For every 4°C raise in air inlet temperature of an air compressor, the power consumption will increases by_____ a) 2% b) 1% c) 3% d) 4% Answer : b) 1%...
Identify the correct statement for air compressors. a. For every 5.5oC drop in the inlet air temperature, the increase in energy consumption is by 2%. b. For every 4 oC rise in ... increase in energy consumption is by 1% d. The energy consumption remains same irrespective of inlet air temperature Answer : c. For every 4 oC rise in the inter air temperature, the increase in energy consumption is by 1% ...
The percentage increase in power consumption of a compressor with suction side air filter and with the pressure drop across the filter of 200 mmWc is ____ a) 1.0% b) 3% c) 2.4% d) 1.6% Answer : d) 1.6%...
From base load operation and from achieving best specific energy consumption point of view, which of the following compressors are suitable? a) Single stage reciprocating compressors b) Centrifugal compressors c) Two stage reciprocating compressor d) Multi stage reciprocating compressor Answer : b) Centrifugal compressors...
From the point of lower specific energy consumption, which of the following compressors are suitable for part load operation? a) Two stage reciprocating compressors b) Centrifugal compressors c) Two stage screw compressor d) Single stage screw compressor Answer : a) Two stage reciprocating compressors...