From base load operation and from achieving best specific energy consumption point of view, which of the following compressors are suitable? a) Single stage reciprocating compressors b) Centrifugal compressors c) Two stage reciprocating compressor d) Multi stage reciprocating compressor
0 like 0 dislike

1 Answer

b) Centrifugal compressors
0 like 0 dislike

Related questions

From the point of lower specific energy consumption, which of the following compressors are suitable for part load operation? a) Two stage reciprocating compressors b) Centrifugal compressors c) Two stage screw compressor d) Single stage screw compressor
Answer : a) Two stage reciprocating compressors...

View solution
0 like 0 dislike
1 answer

Which of the statement is True for centrifugal compressors? a) The compressor should not be operated at full load b) The compressor should be operated at shut off pressure c) The ... operated with inlet-guide vane control d) The compressor should not be operated close to the surge point 
Answer : d) The compressor should not be operated close to the surge point...

View solution
0 like 0 dislike
1 answer

Why inter-coolers are required for multi-stage reciprocating compressors?  
Answer : The intercoolers reduce the temperature of air/gas discharged between stages. Ideally, the intake temperature at each stage should be the same as that at the first stage (referred to a perfect cooling), so that the volume of air to be compressed does not increase and hence reduced power consumption....

View solution
0 like 0 dislike
1 answer

What is the effect of increase in altitude on the performance of single stage reciprocating compressors? 
Answer : With the increase in altitude, there will be reduction in air pressure, which results in increase in compression ratio, leading to higher discharge temperature and reduced efficiency. ...

View solution
0 like 0 dislike
1 answer

What are the limitations of a centrifugal compressor operation? 
Answer : The major limitation of a centrifugal compressor is that is operates at peak efficiency at design point only and any deviation from the operating point is detrimental to its performance. When selecting ... at high pressure, with the consequent reduction in flow, the surge point is not reached....