The likely estimate on equivalent power wastage for a leakage from 7 bar compressed air system through 1.6 mm orifice size is ____ a) 0.2 kW b) 3.0 kW c) 0.8 kW d) 12 kW Answer : c) 0.8 kW...
Explain about the importance of optimal Pressure settings of a compressed air network Answer : The power consumed by a compressor depends on its operating pressure and rated capacity. They should not be operated above their optimum operating pressure as this not only wastes energy, but also leads ... switches must be adjusted such that the compressor cut-in and cuts-off at optimum levels. ...
The percentage increase in power consumption of a compressor with suction side air filter and with the pressure drop across the filter of 200 mmWc is ____ a) 1.0% b) 3% c) 2.4% d) 1.6% Answer : d) 1.6%...
Reduction in the delivery pressure of a Compressor working at 7 bar, by 1 bar would reduce the power consumption by a) 6 to 10 % b) 2 to 3 % c) 12 to 14 % d) None of the above Answer : a) 6 to 10 %...
Identify the correct statement for air compressors. a. For every 5.5oC drop in the inlet air temperature, the increase in energy consumption is by 2%. b. For every 4 oC rise in ... increase in energy consumption is by 1% d. The energy consumption remains same irrespective of inlet air temperature Answer : c. For every 4 oC rise in the inter air temperature, the increase in energy consumption is by 1% ...
50.5k questions
47.1k answers
240 comments
7.0k users