Which of the statement is “True” for centrifugal compressors? a) The compressor should not be operated at full load b) The compressor should be operated at shut off pressure c) The compressor should not be operated with inlet-guide vane control d) The compressor should not be operated close to the surge point 
0 like 0 dislike

1 Answer

d) The compressor should not be operated close to the surge point
0 like 0 dislike

Related questions

From the point of lower specific energy consumption, which of the following compressors are suitable for part load operation? a) Two stage reciprocating compressors b) Centrifugal compressors c) Two stage screw compressor d) Single stage screw compressor
Answer : a) Two stage reciprocating compressors...

View solution
0 like 0 dislike
1 answer

From base load operation and from achieving best specific energy consumption point of view, which of the following compressors are suitable? a) Single stage reciprocating compressors b) Centrifugal compressors c) Two stage reciprocating compressor d) Multi stage reciprocating compressor
Answer : b) Centrifugal compressors...

View solution
0 like 0 dislike
1 answer

What is a surge point and how do you prevent surging, in centrifugal compressors?
Answer : Surge point is the point on the performance curve where a further decrease inflow (typically in the region of 50-70 % of rated capacity) causes instability, resulting in a pulsating flow, ... to thrust reversals, or excessive vibration. Bypass valves advents are commonly used to prevent surging. ...

View solution
0 like 0 dislike
1 answer

Identify the correct statement for air compressors. a. For every 5.5oC drop in the inlet air temperature, the increase in energy consumption is by 2%. b. For every 4 oC rise in ... increase in energy consumption is by 1% d. The energy consumption remains same irrespective of inlet air temperature 
Answer : c. For every 4 oC rise in the inter air temperature, the increase in energy consumption is by 1% ...

View solution
0 like 0 dislike
1 answer

What are the methods of capacity control in centrifugal air compressors?  
Answer : Centrifugal compressors operate best at the design point. They are prone to surging at flow rates less than 50% of the rated capacity. The following types of controls are employed in ... variable speed drives to match compressor output to meet varying load requirements is by speed control ...