Describe the construction and working of two pass flow surface condenser also write it’s function and location in steam power plant.
0 like 0 dislike

1 Answer

image

Construction: It consists of horizontal cast iron cylindrical vessel pack with tubes, through which the cooling water flows. The ends of the condenser are cut off by vertical perforated type plates in to which water tubes are fixed. This is done in such a manner that the leakage of water in to the center condensing space is prevented.

Working: The water tubes pass horizontally through the main condensing space for the steam. The steam enters at the top & is forced to flow downwards over the tubes due to the suction of the extraction pump at the bottom. The cooling water flows in one direction through lower half of the tubes & return in opposite direction through the upper half as shown in figure. The condensate does not mix with cooling water which is used for cooling steam & Convert into water; therefore whole condensate can be the reused in the boiler.

Function: It is used to increase the turbine output by maintaining backpressure on exhaust side of steam engine or turbine & the secondary function of condenser is to supply pure and hot feed water to boiler.

Location in steam power plant- between turbine and feed pump 

0 like 0 dislike

Related questions

Describe with neat sketch the construction and working of surface condenser
Answer : Construction- It consists of horizontal cast iron cylindrical vessel pack with tubes, through which the cooling water flows. The ends of the condenser are cut off by vertical perforated type plates into ... ; the secondary function of condenser is to supply pure and hot feed water to boiler.   ...

View solution
0 like 0 dislike
1 answer

(i) Draw the neat sketch of bomb calorimeter. (ii) Write any three sources of air leakage in steam condenser.
Answer : (i)   (ii) Sources of air leakage in condenser: i) Air leak through joints and packing. ii) Air also comes in condenser with the steam. iii) In jet condensers dissolved air in the cooling water enters the condenser.  ...

View solution
0 like 0 dislike
1 answer

Explain solar power plant and write its two advantages.
Answer : Construction: The basic components of solar power plant are also exactly identical to thermal power plant except the boiler is replaced by solar collector. The arrangement of component is as shown in figure. The ... free iii) iii) Available all over the world. iv) iv) Less maintenance.   ...

View solution
0 like 0 dislike
1 answer

Describe any two sources of air leak in surface condenser. Also describe effect of air leak on latent heat of steam and cooling water requirements.
Answer : ✓ The main sources of air leakage found in condenser are given below: 1) There is leakage of air from atmosphere at the joint of the parts which are internally under a pressure less ... hence evaporation enthalpy of steam increases therefore more amount of cooling water required in the condenser. ...

View solution
0 like 0 dislike
1 answer

Describe with neat sketch working of air compressor used in automobile workshops. State its two advantages
Answer : As shown in ig. Shows two stages reciprocating air compressor with water cooled and intercooler First of all fresh air is sucked from atmosphere in low pressure (L.P) cylinder during its suction ... :  1) Less power is required to drive the compressor.  2) Higher volumetric efficiency  ...

View solution