0.7 v sil and 0.3 v for gr
A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω Answer : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω ...
Is gate turn on mechanism of GTO is similar to conventional thyristor? Answer : Yes gate turn on mechanism of GTO is similar to conventional thyristor....
Answer : GTO can be turned on by providing positive pulse to the gate terminal and it can be turn off by providing negative pulse to gate terminal....
Minimum voltage regulation occurs when the power factor of the load is? Answer : Minimum voltage regulation occurs when the power factor of the load is leading. ...
Draw the structural diagram of GTO. Explain briefly the switching behavior of GTO with the help of appropriate voltage and current waveform. Answer : Gate Turn Off Thyristor (GTO) Conventional Thyristor can be turned on with gate terminal but can not turn off from gate terminal. But in case of Gate Turn Off Thyristor (GTO), we can turn it on and off ... subdivided as storage period (Ts), fall period (Tp) and tail period (Tt). ...