In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in

(A) voltage notching (B) harmonic distortion

(C) voltage sag (D) voltage swell
0 like 0 dislike

1 Answer

In a 3-phase converter circuit during commutation when one SCR in one phase is turned on to turn-off an SCR in another phase, results in voltage notching

0 like 0 dislike

Related questions

A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is (A) 4.5 V (B) 6.75 V (C) 9 V (D) 13.5 V
Answer : A 230 V, 50 Hz phase controlled single-phase full-controlled SCR bridge converter draws 15 A constant dc current. If the source inductance is 3 mH, the drop in dc output voltage is 9 V ...

View solution
0 like 0 dislike
1 answer


Answer : SCR turned off when the anode current falls below holding current. ...

View solution
0 like 0 dislike
1 answer

The SCR would be turned OFF by voltage reversal of applied anode-cathode ac supply frequency of A) 10 kHz B) 10 Hz C) 5 kHz D) 5 Hz 

View solution
0 like 0 dislike
0 answers

Describe the gate circuit for a single phase full converter.

View solution
0 like 0 dislike
0 answers

The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ ...

View solution
0 like 0 dislike
1 answer

50.5k questions