Phantom loading for testing of energy meter is used

(A) to isolate the current and potential circuits

(B) to increase power loss during testing

(C) for meters having low current ratings

(D) to test meters having a large current rating for which loads may not be available
0 like 0 dislike

2 Answers

Phantom loading for testing of energy meter is used to test meters having a large current rating for which loads may not be available

0 like 0 dislike
B
0 like 0 dislike

Related questions

With neat diagram explain calibration of energy meter by direct loading method.
Answer : Calibration of Energy Meter by Direct Loading Method:  There are three methods for testing/calibration:  1. Long period dial test  2. Using rotary sub- standard meter  3. Using precision grade instruments  All ... of substandard meter in kWh  Then % error = [(D - DS)/DS] x 100 ...

View solution
0 like 0 dislike
1 answer

State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet
Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. ...

View solution
0 like 0 dislike
1 answer

Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 
Answer : Energy conservation techniques to reduce commercial losses:  1. Mitigation of Power Theft: Power theft being the most important issue which all of the service providing utilities ... agricultural sector. Prepaid meters may prove effective measures against unauthorized abstraction of energy.  ...

View solution
0 like 0 dislike
1 answer

List any four errors in induction type energy meter. Give method of compensation for each.
Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet.  ...

View solution
0 like 0 dislike
1 answer

An induction type energy meter is found to run fast. Correction for this error can be made by  (A) Over-load compensation. (B) Voltage compensation. (C) Moving the brake magnet away from the centre of the disc. (D) Moving the brake magnet towards the centre of the disc.
Answer : An induction type energy meter is found to run fast. Correction for this error can be made by Moving the brake magnet away from the centre of the disc. ...

View solution
0 like 0 dislike
1 answer

50.5k questions

47.1k answers

240 comments

7.0k users