During periodic testing of an AT weld with 700 probe, a bunch of moving signals of

less than 40% but more than 10% is observed in the head of weld, the joint will be.
(i) Good joint.*
(ii) DFWR
(iii) DFWO
(iv) OBSW
0 like 0 dislike

1 Answer

i) Good joint.*
0 like 0 dislike

Related questions

On a branch line one new AT Weld with 00 probe shows a signal of 58 is. (i) DFWO* (ii) DFWR (iii) IMRW (iv) OBSW
Answer : i) DFWO*...

View solution
0 like 0 dislike
1 answer

By 00 probe in AT weld testing with normal gain setting. (i) Area below N.axis can be tested. (ii) Area below N.axis can not be tested.* (iii) Only web below N.axis can be tested. (iv) All above are correct.
Answer : (ii) Area below N.axis can not be tested.*...

View solution
0 like 0 dislike
1 answer

After declare good in USFD testing what is the joggling criteria ? (i) Joggle will be open from the AT weld* (ii) Joggling with two far end bolting (iii) joggling with four tight bold (iv) None of the above
Answer : (i) Joggle will be open from the AT weld*...

View solution
0 like 0 dislike
1 answer

Side looking 700 2MHZ probe is tested for detecting. (i) Flaw in head (ii) Flaw in web (iii) Half moon crack in flange.* (iv) For all above.
Answer : iii) Half moon crack in flange...

View solution
0 like 0 dislike
1 answer

Defect of low joint is due to? (i) Excess height (ii) Early trimming of weld (iii) Early grinding of weld (iv) Nil/Less provision of height during alignment.
Answer : (iv) Nil/Less provision of height during alignment....

View solution
0 like 0 dislike
1 answer

50.5k questions