On a branch line one new AT Weld with 00 probe shows a signal of 58 is.
(i) DFWO*
(ii) DFWR
(iii) IMRW
(iv) OBSW
0 like 0 dislike

1 Answer

i) DFWO*
0 like 0 dislike

Related questions

During periodic testing of an AT weld with 700 probe, a bunch of moving signals of less than 40% but more than 10% is observed in the head of weld, the joint will be. (i) Good joint.* (ii) DFWR (iii) DFWO (iv) OBSW
Answer : i) Good joint.*...

View solution
0 like 0 dislike
1 answer

By 00 probe in AT weld testing with normal gain setting. (i) Area below N.axis can be tested. (ii) Area below N.axis can not be tested.* (iii) Only web below N.axis can be tested. (iv) All above are correct.
Answer : (ii) Area below N.axis can not be tested.*...

View solution
0 like 0 dislike
1 answer

Marking of DFWO weld is. (i) Two red point circle on both faces of weld.* (ii) Two red point cross on both faces of weld. (iii) One red point circle on both faces of weld. (iv) None of the above.
Answer : i) Two red point circle on both faces of weld.*...

View solution
0 like 0 dislike
1 answer

Tandem rig test with 450 probe for AT weld detects. (i) Horizontal longitudinal defect in weld. (ii) Vertical oriented defect in AT weld.* (iii) Transverse defect in AT weld. (iv) Defect in flange of AT welds.
Answer : (ii) Vertical oriented defect in AT weld.*...

View solution
0 like 0 dislike
1 answer

DFWR weld shall be replaced. (i) Within 2 months of detection. (ii) Within 1 year of detection. (iii) Within 3 months of detection.* (iv) after 3 days of detection.
Answer : (iii) Within 3 months of detection.*...

View solution
0 like 0 dislike
1 answer