Tandem rig test with 450 probe for AT weld detects.
(i) Horizontal longitudinal defect in weld.
(ii) Vertical oriented defect in AT weld.*
(iii) Transverse defect in AT weld.
(iv) Defect in flange of AT welds.
0 like 0 dislike

1 Answer

(ii) Vertical oriented defect in AT weld.*
0 like 0 dislike

Related questions

450 probe is used for detecting defect in; (i) FB weld (ii) AT weld (iii) FB weld, AT weld & SEJ (iv) All above*
Answer : (iv) All above*...

View solution
0 like 0 dislike
1 answer

Min. breaking load of 60kg weld during transverse breaking load test is? (i) 110 MT (ii) 115 MT* (iii) 90 MT (iv) 120 MT
Answer : (ii) 115 MT*...

View solution
0 like 0 dislike
1 answer

Min. breaking load of 52kg weld during transverse breaking load test is? (i) 90MT* (ii) 100 MT (iii) 110 MT (iv) 120 MT
Answer : (i) 90MT*...

View solution
0 like 0 dislike
1 answer

If digital DRT is calibrated for 300 mm longitudinal wave using 00 double crystal probe then 60kg rail ---------peak will appear at (i) 5.2 (ii) 5.7* (iii) 7.8 (iv) 8.6
Answer : ii) 5.7*...

View solution
0 like 0 dislike
1 answer

During periodic testing of an AT weld with 700 probe, a bunch of moving signals of less than 40% but more than 10% is observed in the head of weld, the joint will be. (i) Good joint.* (ii) DFWR (iii) DFWO (iv) OBSW
Answer : i) Good joint.*...

View solution
0 like 0 dislike
1 answer

50.5k questions

47.1k answers

240 comments

7.0k users